Built-in ventilation systems

1.00лв.11.00лв.

Lossnay is evolving with a steady look ahead to the air conditioning needs of the age, which are becoming increasingly diverse. The technology finds a wide range of applications and the bodies are well adapted in residential buildings, offices, hospitals, schools, etc.

The energy saved through the use of Lossnay contributes directly to lower heating and cooling consumption. The sensitive heat exchanger effectively reduces excess moisture in winter.

LGH-15RVX-E

  • *

    Flow rate [m3/h]150 - 113 - 75 - 38
    External static pressure [Pa]95 - 54 - 24 - 6
    Power consumption [W]49 - 28 - 14 - 7
    Heat exchange efficiency [%]80 - 81 - 83 - 84
    Heating enthalpy exchange efficiency [%]73 - 75.5 - 78 - 79
    Cooling enthalpy exchange efficiency [%]71 - 74.5 - 78 - 79
    Dimensions [mm]780 - 610 - 289
    Weight [kg]20
    Noise levels [dB(A)]28 - 24 - 19 - 17
    Power supply220 - 240V / 50 Hz
    Energy efficiency classA
    Price (with VAT without installation)2 049.00 BGN

LGH-25RVX-E

  • *

    Flow rate [m3/h]250 - 188 - 125 - 63
    External static pressure [Pa]85 - 48 - 21 - 5
    Power consumption [W]62 - 33 - 16 - 7.5
    Heat exchange efficiency [%]79 - 80 - 82 - 86
    Heating enthalpy exchange efficiency [%]69.5 - 72 - 76 - 83
    Cooling enthalpy exchange efficiency [%]68 - 70 - 74.5 - 83
    Dimensions [mm]780 - 735 - 289
    Weight [kg]23
    Noise levels [dB(A)]27 - 22 - 20 - 17
    Power supply220 - 240V / 50 Hz
    Energy efficiency classA
    Price (with VAT without installation)2 949.00 BGN

LGH-35RVX-E

  • *

    Flow rate [m3/h]350 - 263 - 175 - 88
    External static pressure [Pa]160 - 90 - 40 - 10
    Power consumption [W]140 - 70 - 31 - 11
    Heat exchange efficiency [%]80 - 82.5 - 86 - 88.5
    Heating enthalpy exchange efficiency [%]71.5 - 74 - 78.5 - 83.5
    Cooling enthalpy exchange efficiency [%]71 - 73 - 78 - 82
    Dimensions [mm]888 - 874 - 331
    Weight [kg]30
    Noise levels [dB(A)]32 - 28 - 20 - 17
    Power supply220 - 240V / 50 Hz
    Price (with VAT without installation)4 099.00 BGN

LGH-50RVX-E

  • *

    Flow rate [m3/h]500 - 375 - 250 - 125
    External static pressure [Pa]120 - 68 - 30 - 8
    Power consumption [W]165 - 78 - 32 - 12
    Heat exchange efficiency [%]78 - 81 - 83.5 - 87
    Heating enthalpy exchange efficiency [%]69 - 71 - 75 - 82.5
    Cooling enthalpy exchange efficiency [%]66.5 - 68 - 72.5 - 82
    Dimensions [mm]888 - 1016 - 331
    Weight [kg]33
    Noise levels [dB(A)]34 - 28 - 19 - 18
    Power supply220 - 240V / 50 Hz
    Price (with VAT without installation)4 649.00 BGN

LGH-65RVX-E

  • *

    Flow rate [m3/h]650 - 488 - 325 - 163
    External static pressure [Pa]120 - 68 - 30 - 8
    Power consumption [W]252 - 131 - 49 - 15
    Heat exchange efficiency [%]77 - 81 - 84 - 86
    Heating enthalpy exchange efficiency [%]68.5 - 71 - 76 - 82
    Cooling enthalpy exchange efficiency [%]66 - 69.5 - 74 - 81
    Dimensions [mm]908 - 954 - 404
    Weight [kg]38
    Noise levels [dB(A)]34.5 - 29 - 22 - 18
    Power supply220 - 240V / 50 Hz
    Price (with VAT without installation)6 549.00 BGN

LGH-80RVX-E

  • *

    Flow rate [m3/h]800 - 600 - 400 - 200
    External static pressure [Pa]150 - 85 - 38 - 10
    Power consumption [W]335 - 151 - 60 - 18
    Heat exchange efficiency [%]79 - 82.5 - 84 - 85
    Heating enthalpy exchange efficiency [%]71 - 73.5 - 78 - 81
    Cooling enthalpy exchange efficiency [%]70 - 72.5 - 78 - 81
    Dimensions [mm]1144 - 1004 - 404
    Weight [kg]48
    Noise levels [dB(A)]34.5 - 30 - 23 - 18
    Power supply220 - 240V / 50 Hz
    Price (with VAT without installation)7 199.00 BGN

LGH-100RVX-E

  • *

    Flow rate [m3/h]1000 - 750 - 500 - 250
    External static pressure [Pa]170 - 96 - 43 - 18
    Power consumption [W]420 - 200 - 75 - 21
    Heat exchange efficiency [%]80 - 83 - 86.5 - 89.5
    Heating enthalpy exchange efficiency [%]72.5 - 74 - 78 - 87
    Cooling enthalpy exchange efficiency [%]71 - 73 - 77 - 85.5
    Dimensions [mm]1144 - 1231 - 404
    Weight [kg]54
    Noise levels [dB(A)]37 - 31 - 23 - 18
    Power supply220 - 240V / 50 Hz
    Price (with VAT without installation)7 849.00 BGN

LGH-150RVXT-E

  • *

    Flow rate [m3/h]1500 - 1125 - 750 - 375
    External static pressure [Pa]175 - 98 - 44 - 11
    Power consumption [W]792 - 421 - 176 - 48
    Heat exchange efficiency [%]80 - 80.5 - 81 - 81.5
    Heating enthalpy exchange efficiency [%]70 - 71 - 73 - 75
    Cooling enthalpy exchange efficiency [%]69 - 70 - 72 - 74
    Dimensions [mm]1500 - 1980 - 500
    Weight [kg]156
    Noise levels [dB(A)]39.5 - 35.5 - 29.5 - 22
    Power supply220 - 240V / 50 Hz
    Price (with VAT without installation)13 129.00 BGN

LGH-200RVXT-E

  • *

    Flow rate [m3/h]2000 - 1500 - 1000 - 500
    External static pressure [Pa]175 - 98 - 44 - 11
    Power consumption [W]1000 - 494 - 197 - 56
    Heat exchange efficiency [%]80 - 81 - 82.5 - 84
    Heating enthalpy exchange efficiency [%]72.5 - 73.5 - 77 - 83
    Cooling enthalpy exchange efficiency [%]70 - 71 - 74.5 - 80.5
    Dimensions [mm]1500 - 1980 - 500
    Weight [kg]159
    Noise levels [dB(A)]39.5 - 35.5 - 28 - 22
    Power supply220 - 240V / 50 Hz
    Price (with VAT without installation)14 249.00 BGN

LGH-250RVXT-E

  • *

PZ-62DR-E

  • *

    Remote control for Lossnay series
    FunctionsManage 1 to 15 Lossnay bodies
    Dimensions [mm]120 - 120 - 19
    Price (with VAT without installation)560.00 BGN

Product total

Options total

Grand total